Can I plaster PROMAFOUR® boards around fireplaces and woodburning stoves?
We would not recommend plastering PROMAFOUR® boards, because even high temperature plasters tend to crack and craze over time. PROMAFOUR® boards are supplied with a smooth finish on one side, which is suitable for direct application of PROMAFOUR® PRIMER. Additional paint treatments suitable for use in high temperature environments can then be appl
-
What is Regulatory Reform (Fire Safety) Order?
The Regulatory Reform (Fire Safety) Order came into force on 1st October 2006 and brings together the many pieces of fire legislation under one document. It covers fire safety within all public premises, office and commercial buildings. The order puts the responsibility for fire safety on the building owner or occupier, or ‘responsible person’ and r
-
How do I request a Promat RIBA accredited CPD presentation?
Please click here to request a RIBA accredited CPD presentation.
-
Can you supply me with detailed CAD drawings of DURASTEEL® Installations?
DURASTEEL® is only supplied and installed through our Licensed Installers. They will create CAD drawings based on site measurements and the exact requirements as presented on site. Promat can supply generic details to illustrate the main principles of construction and overall thickness. Please e-mail our Technical Services Team for more details.
-
Can DURASTEEL® provide a blast resistant construction?
DURASTEEL® can be used to build walls and ceilings which are required to withstand blast. Please e-mail in the requirements and our Technical Services Team can investigate further.
-
How much does DURASTEEL® cost?
DURASTEEL® systems are designed based on factors such as the required fire rating, blast rating, application, site conditions and access. Our Licensed Installers for DURASTEEL® can provide a quote based on your system requirements.
-
How do I provide 240 minutes fire stopping that would be suitable to be installed around HV cables from a UKPN substation into next door space?
from Etex To provide fire stopping and blast protection to the opening in a UKPN transformer room a combination of two products supplied by Etex are required; The void is filled using PROMAT FSI SILVERSEAL HS COMPOUND 2. A pattress of DURASTEEL® is then fixed over the Compound and cut tightly around the cables and overlapped on all sides by 1
-
I don't have space to apply the additional 4.8mm hardboard above the line of my existing square-edged flooring within a Supalux® timber joisted floor construction. Is there an alternative?
If the installation of 4.8mm thick hardboard flooring above the line of existing flooring within a SUPALUX® timber joisted floor system isn't practical, our suggested solution would be to apply it below the line of the existing flooring. It should be mechanically fixed, tightly between the joists, and sealed with a bead of FSi PRYOCOUSTIC® fire resi
-
How do I know if I have primed the whole board when applying a plaster finish?
A good way to know if full coverage of the board has been achieved when priming is to add food dye to the PVA. For our recommendations on applying finishes to our boards, see our Technical Data Sheet .
-
Do you need to be an approved/accredited installer to work with Promat fire protection boards?
We have no specific training and certification requirements for installing Promat fire protection boards. Our standard requirement is that the installers are competent and experienced in the installation of passive fire protection systems. On this basis, the contractor should be recognised and registered by a third-party scheme such as FIRAS. The sc
-
Do Promat have solutions for upgrading the fire performance of timber doors?
Promat no longer have a solution for upgrading the fire performance of existing timber doors. We would suggest you contact BM Trada , one of the leading specialists in timber doors upgrade who should be able to provide you with further assistance.
-
Can I paint PROMAFOUR® boards?
Yes, we recommend that PROMAFOUR® boards are painted with high-temperature paint. A base coat of PROMAFOUR® PRIMER can be used first. Contact Keim Paint for finishing coats, who are one of the specialist suppliers for mineral paints.
-
Can I fix the SUPALUX® self-supporting ceiling membrane system to drylined walls?
No, as the standard requirement for the perimeter of any of the SUPALUX® passive fire protection systems is that they must be fixed back to a solid, load-bearing element of the construction of equal or greater fire performance. This would include a concrete or masonry wall. The system can also be fixed to structural steel which has been fire protec
-
What staples can I use for PROMATECT®-250?
The Chisel Point Staples and guns required to fix PROMATECT®-250 boards are manufactured by Paslode. The specification for the staples is: 35mm long x 12mm wide x 1.6mm thick staples for boards up to 15mm thick (product code: 054522), and 50mm long x 12mm wide x 1.6mm thick staples for boards above 15mm thick (product code: 012302). The gun used for
-
What staples can I use with PROMATECT®-XW?
The Chisel Point Staples and guns required to fix PROMATECT®-XW boards are manufactured by Paslode. The specification for the staples is: 35mm long x 12mm wide x 1.6mm thick staples (product code: 054522). The gun used for this staple size is the Paslode IM200 (product code: 900078). Some companies who stock the Paslode products are: Sitebox Ltd - 0
-
Can I Dot & Dab onto SUPALUX® boards?
Promat SUPALUX® has a high suction and it is not possible to dot & dab on the surface of the board because failure of the bond may occur. You will need to batten out first making sure the battens are fixed to the substrate supporting the SUPALUX® boards and not rely on face fixing into the boards.
-
Who are Promat's regional Technical Specification Representatives?
Promat have technical sales support covering the whole of the UK & ROI through an ASM (Architectural Specification Manager) network. The area covered by each ASM and their contact details are listed below: Scott Macswan Scotland Architectural Specification Manager E: scott.macswan@etexgroup.com M: +44 (0)7392 315 317 Martin Wrigley Midla
-
Can you use protection board encasements around steelwork when there is bracketry fixed directly to the columns and/or beams?
Our recommended solution for this situation would be to ensure that where any bracketry is connected to the structural steel, these locations should coincide with the board joints for the steelwork encasements. This will allow the encasement boards to be notched around the ties with the smallest possible gaps between the ties and the boards – betwe
-
Can I tile on Vermiculux® -S board?
No, Vermiculux®-S board surface is not suitable for tiling, and tiles should not be fixed directly back to the fire protection boards. We would suggest tiles should be fixed to a separate frame/board system, supported independent of the desired system.
-
Can I tile on Promatect®-250 board?
No, Promatect®-250 board surface is not suitable for tiling, and tiles should not be fixed directly back to the fire protection boards. We would suggest tiles should be fixed to a separate frame/board system, supported independent of the desired system.
-
Can I tile on Promatect®-L500 board?
No, Promatect®-L500 board surface is not suitable for tiling, and tiles should not be fixed directly back to the fire protection boards. We would suggest tiles should be fixed to a separate frame/board system, supported independent of the desired system.
-
Can I tile on Masterboard®?
Yes, Masterboard® can be tiled with ceramic, marble, granite and natural stone tiles. In order to tile successfully, please refer to TDS 56 - Promat Board Finishes on our Documentation page.
-
Can Promat TLFR Board® be used to upgrade the thermal performance of concrete walls?
Promat TLFR Board® is mainly used for upgrading the thermal performance of concrete soffits. If, however, you require a thermal performance upgrade of concrete walls, the TLFR Board® could be used, but be aware that the fixings are surface mounted and the joints will be visible because it is not possible to tape and joint the boards. The type of fix
-
Where can I find a fire integrity access panel for a DURASTEEL® duct?
Advanced Smoke Group (ASG) manufacture an access panel called DURAFIRE® AD that has been tested for installation within DURASTEEL® ductwork systems to provide up to 240 minutes fire integrity only to BS 476: Part 22: 1987. A data sheet for the panel can be found at this link.
-
What is the recommended jointing method for MASTERBOARD®?
All the joints and any screw fixing heads can be feathered and filled using Promat moisture resistant ready mixed joint filler.
-
Can I install a Supalux® timber joisted roof void detail to a sloping roof?
This type of ceiling system is only intended for use on horizontal timber roof joist elements and not for sloping roofs. The testing and certification we have for these systems, rated at 30, 60 and 120 minutes integrity and insulation, does not include installation at an angle and doesn't readily lend itself to the dimensions normally associated wit
-
What type of board edge is Masterboard® finished with?
Masterboard® is finished with a square board edge, it is available in 6mm, 9mm and 12mm thicknesses, at 2440x1220mm sheet size.
-
How do I prime Promat boards before applying a plaster finish?
All Promat boards tend to have a high suction and therefore it is generally difficult to apply gypsum plaster. Traditionally PVA has been used, apply a number of sealing coats of diluted universal primer/PVA (e.g. 1 part PVA and 5 parts water). Sealing coats should be allowed to dry thoroughly (approximately 24 hours). Then apply a bonding coat (3 p
-
Is it possible to install Promat boards with a bend radius?
We would not recommend bending our boards as they are dense, rigid calcium silicate boards. We would be unable to guarantee the fire performance of any board that has been formed into a radius, within any of our systems, as this would fall outside the scope of our testing and certification.
-
Can the SUPALUX® Suspended Membrane Ceiling be fixed into a stud partition at the perimeter?
The tested construction, includes perimeter angles for the SUPALUX® Suspended Membrane Ceiling that are fixed into a solid, loadbearing element of the building construction that's of equal or greater fire performance to the ceiling system, on all four sides. This is typically a concrete/blockwork/brickwork/masonry wall, but can also be suitably fire
-
Where can I buy M5.5 TEK screws for fixing DURASTEEL®?
The M5.5 Self-Drill & Tap TEK screws required for fixing DURASTEEL® can be supplied by Evolution Fasteners UK Ltd or other similar manufacturer. The fixings can be found here: M5.5 Self-Drill & Tap TEK Screws: https://evolutionfasteners.co.uk/Products/?categories=2&SingleProduct=10073 M5.5 Self-Drill & Tap CSK TEK Screws: https://ev
-
Where can I buy flat-head steel nails/steel woodscrews for fixing Promat boards to timber?
Flat-head steel nails: These can be supplied by Spit Paslode or other similar manufacturer. They can be found using the following link. Their contact details are: Tel: 0800 833 381 M4/M5 steel woodscrews: These can be supplied by Evolution Fasteners UK Ltd or other similar manufacturer. They can be found using the following link. Their contact det
-
Where can I buy M5.5 timber-deck winged self-drilling screws for fixing timber flooring to steel framing?
These can be supplied by Evolution Fasteners UK Ltd or other similar manufacturer. They can be found using the following link. Their contact details are: Email: sales@evolutionfasteners.co.ukTel: 0141 647 7100
-
Where can I buy M4 CSK self-tapping/drilling screws for fixing Promat board to steel framing?
These can be supplied by our sister company Siniat or other similar manufacturer. M4 CSK self-tapping can be viewed here. (for up to 0.7mm gauge metal framing) M4 CSK self-drilling can be viewed here. (for above 0.7mm gauge metal framing) Their contact details are: Email: technical@siniat.co.ukTel: 01275 377773
-
Where can I buy concrete screws for fixing Promat board to concrete/masonry?
M4 concrete screws These can be supplied by Screwfix or other similar supplier. They can be viewed using this link. Their contact details are: Tel: 03330 112 112 M6 concrete screws These can be supplied by RS PRO or other similar supplier. They can be viewed using this link. Their contact details are: Tel: 03457 201201
-
Where can I buy metal/non-combustible wall plugs for fixing Promat board to concrete/masonry?
M5 metal/non-combustible wall plugs These can be supplied by Screwfix or other similar supplier. They can be found using this link. Their contact details are: Tel: 03330 112 112 M6 metal/non-combustible wall plugs These can be supplied by Fischer or other similar manufacturer. They can be found using this link. Their contact details are: Email: s
-
Where can I buy 3.7x16mm Shot Fire Nails for fixing steel framing to structural steel?
These can be supplied by Spit Paslode or other similar manufacturer. They can be viewed using the following link. Their contact details are: Tel: 0800 833 381https://www.paslode.co.uk/
-
Where can I buy M4x10mm Wafer Head Screws for fixing steel framing to structural steel?
These can be supplied by our sister company Siniat or other similar manufacturer. They can be found at the following link. Their contact details are: Email: technical@siniat.co.ukTel: 01275 377773
-
Where can I buy blind rivets for fastening steel framing to steel framing?
M4 Blind Rivets These can be supplied by Accu or other similar supplier. They can be found using this link. M5 Blind Rivets These can be supplied by Accu or other similar supplier. They can be found using this link. Their contact details are:Tel: 01484 937010
-
Where can I buy self-tapping screws for fastening steel framing to steel framing?
M4 Self-Tapping Screws These can be supplied by RS PRO or other similar supplier. They can be found using this link. No.8 Self-Drilling/Tapping Screws These can be supplied by RS PRO or other similar supplier. They can be found using this link. The contact details of RS PRO are: Tel: 03457 201201
-
Where can I buy M4 drywall high thread screws for fixing Promat boards together?
These can be supplied by our sister company Siniat or other similar manufacturer. They can be found using this link. Their contact details are: Email: technical@siniat.co.ukTel: 01275 377773
-
Where can I buy anchor bolts for fixing framing used in Promat systems to concrete/masonry?
The sizes of anchor bolts used in Promat systems for fixing framing into concrete/masonry constructions are M6, M8, M10 and M12. These can be supplied by Fischer or other similar manufacturer. They can be found using this link. Their contact details are: Email: sales@fischer.co.ukTel: +44 1491 827 900
-
Where can I buy expanding sleeve anchor bolts for fixing framing used in Promat systems to concrete/masonry?
The sizes of expanding sleeve anchor bolts used in Promat systems for fixing framing into concrete/masonry constructions are M8, M10 and M12. These can be supplied by Fischer or a similar manufacturer. They can be seen using this link. Their contact details are: Email: sales@fischer.co.ukTel: +44 1491 827 900
-
Where can I buy through bolts for fixing framing used in Promat systems to concrete/masonry?
The size of through bolt used in Promat systems to fix framing to a concrete/masonry construction is M6. These can be supplied by Fischer or other similar manufacturer. They can be found using this link. Their contact details are: Email: sales@fischer.co.ukTel: +44 1491 827 900
-
If the flooring grade chipboard above the PROMATECT®-250 steel joisted mezzanine floor is less than 38mm thick would it be acceptable to overboard the floor with an additional layer of flooring grade chipboard?
Yes, it is acceptable to overboard the existing floor with a layer of flooring grade chipboard so that the minimum depth of 38mm is achieved. The joints of the new layer of flooring grade chipboard should be staggered with joints of the board already installed, and fixed through the existing boards to the galvanised steel joists using timber-deck w
-
Can I use stainless steel staples to fix Promat PROMATECT®-250 or PROMATECT®-XW fire protection boards?
Yes it is acceptable to use stainless steel staples for fixing these boards. The specification for the staples for fixing PROMATECT®-250 and PROMATECT®-XW boards is: 35mm long x 12mm wide x 1.6mm thick staples for boards up to 15mm thick, and 50mm long x 12mm wide x 1.6mm thick staples for boards above 15mm thick. These can be sourced using the belo
-
What staples can I use for PROMATECT®-H?
The Galvanised Chisel Point Staple sizes required to fix PROMATECT-H® boards when upgrading the fire performance of concrete columns or beams are: 30mm long x 10.5mm wide x 1.4mm thick staples for 12mm thick boards and 50mm long x 10.5mm wide x 1.4mm thick staples for 25mm thick boards. A company who manufacture a staple that complies with these min